The primary coil of an ideal stepup transformer has 100 turns and the transformer ratio is also 100. The input voltage and power are 220 V and 1100 W. Calculate (i) number of turns in secondary (ii) current in primary (iii) voltage across secondary (iv) current in secondary (v) power in secondary.

A

600

B

500

C

400

D

300

Text Solution

Verified by Experts

The correct Answer is:
D
Promotional Banner

Topper's Solved these Questions

  • MCQS FROM BOARD EXAM

    NIKITA PUBLICATION|Exercise ELECTRONS AND PHOTONS|5 Videos
  • MCQS FROM BOARD EXAM

    NIKITA PUBLICATION|Exercise ATOMS, MOLECULES AND NUCLEI|4 Videos
  • MCQS FROM BOARD EXAM

    NIKITA PUBLICATION|Exercise MAGNETIC EFFECTS OF ELECTRIC CURRENT|4 Videos
  • MAGNETISM

    NIKITA PUBLICATION|Exercise MCQs|249 Videos
  • MH-CET - 2017

    NIKITA PUBLICATION|Exercise CUMMUNICATION SYSTEMS|1 Videos

Similar Questions

Explore conceptually related problems

(i) Write the functions of a transformer . State its principle of working with the help of the a diagram mentions various energy losses in this divice . (ii) The primary coil of an ideal step up transformer has 100 turns and transformation ratio is also 100. The input voltage and power are respectively 220 V and 100w. Calculate (a) number of turns in secodary (b) current in primary ( c) voltage across secodary (d) current in secondary ( e) power in secondary

An ideal step -up transformer has a primarycoil of 120 turns . The transformation ratio is 100 . If the input voltage and power are 230 V and 1000 W respectively, calculate (i) number of turns in the secondary coil . (ii) voltage across the secondary coil. (iii) current in the primary coil . (iv) current in the secondary coil. (v) power in the secondary coil.

In a step - down transformer the input voltage is 22kV and the output voltage is 550V The ratio of the number of turns in the secondary to that in the primary is .

A 66 % efficient transformer is working on 110 V and 2.2 kW power.If current in secondary coil is 6.0 A, calculate (i) current in primary coil and (ii) voltage across secondary coil.

In a step-down transformer having primary to secondary turn ratio 10:1, the input voltage applied is 250V and outout current is 10 A. Assuming 100% efficiency, calculate the (i) voltage across secondary coil (ii) current in primary coil (iii) power output

A transformer has 500 turns in the primary and 1000 turns in its secondary. The primary voltage is 200 V and load in secondary is 100 ohm. Calculate the current in primary assuming it to ideal transformer.

A transformer consists of 500 turn in primary coil and 10 turns in secondary coilk with the load of 10 Omega Find out current in the primary coil when the voltage across secondary coil 50V.

The efficiency of a transformer is 98%. The primary voltage and current are 200 V and 6A . If the secondary voltage is 100 V , the secondary current

A transformer consists of 500 turn in primary coil and 10 turns in secondary coil with the load of 10Omega. Find out current in the primary coil when the voltage across secondary coil is 50 V.