Home
Class 12
PHYSICS
Statement (A) : In high current low volt...

Statement (A) : In high current low voltage windings of a transformer thick wire is used to minimize energy loss due to heat produced
Statement (B) : The core of any transformer is laminated so as to reduce the erergy loss due to eddy currents.

A

`A` is true but `B` is false

B

Both `A` and `B` is true

C

`A` is false but `B`d is true

D

Both `A` and `B` are false

Text Solution

Verified by Experts

The correct Answer is:
2
Promotional Banner

Topper's Solved these Questions

  • ALTERNATING CURRENT

    NARAYNA|Exercise Assertion & Reason|14 Videos
  • ALTERNATING CURRENT

    NARAYNA|Exercise LEVEL - I (C.W)|23 Videos
  • ALTERNATING CURRENT

    NARAYNA|Exercise LEVEL - II(H.W)|13 Videos
  • ATOMIC PHYSICS

    NARAYNA|Exercise LEVEL-II (H.W)|14 Videos

Similar Questions

Explore conceptually related problems

Statement (A) : Flux leakage in a transformer can be minimized by winding the primary and secondary coils one over the other. Statement (B) : Core of the transformer is made of soft iron

Assertion : A laminated core is used in transformers to increase eddy currents. Reason : The efficiency of a transformer increases with increase in eddy currents.

Statement (A) : Step up transformer converts low voltage, high current to high voltage, low current Statement (B) : Transformer works on both ac and dc.

A thermal power plant produed electric power of 600kW at 4000V, which is to be transported to a place 20 km away form the power plant for consumer's usage. It can be transported either directly with a cable of large current carrying capacity or by sing a combination of step-up and step-down transfprmers at the two ends. THe drawback of the direct transmission is the large energy dissipation. In the method wsing transformers, the dissipatiion is much smaller. In this method a step-up transformers is used at the plant side so that the current is reduced to a smaller value. At the consumers'end, a step-down transformer is used to supply power to the consumers at the specified lower voltage. It is reasonable to assume that the power cable is purely resostive and the transformers are ideal with power factor unity. All the currents and voltagementioned are values. If hte direct transmission method with a cable of resistance 0.4(omega) km^(-1) is used, the power dissipation (in %) during transmission is

A thermal power plant produed electric power of 600kW at 4000V, which is to be transported to a place 20 km away form the power plant for consumer's usage. It can be transported either directly with a cable of large current carrying capacity or by sing a combination of step-up and step-down transfprmers at the two ends. THe drawback of the direct transmission is the large energy dissipation. In the method wsing transformers, the dissipatiion is much smaller. In this method a step-up transformers is used at the plant side so that the current is reduced to a smaller value. At the consumers'end, a step-down transformer is used to supply power to the consumers at the specified lower voltage. It is reasonable to assume that the power cable is purely resostive and the transformers are ideal with power factor unity. All the currents and voltagementioned are values. In the method using the transformers assume that the ratio of the number of turns in the primary to that in the secondary in the step-up transformer is 1:10 if the power to the consumers has to be supplied at 200V, the ratio of the number of turns in the primary to that in the secondary in the step-down transformer is

NARAYNA-ALTERNATING CURRENT-C.U.Q
  1. A transformer changes the voltage

    Text Solution

    |

  2. A step up transformer is connected on the primary side to a rechargabl...

    Text Solution

    |

  3. The ratio of primary voltage to secondary voltage in a transformer is ...

    Text Solution

    |

  4. In a step down transformer, the number of turns in the primary is alwa...

    Text Solution

    |

  5. The transformer ratio of a step up transformer is

    Text Solution

    |

  6. A setup transformer develops 440 V in secondary coil for an input of 2...

    Text Solution

    |

  7. Assertion (A) : If changing current is flowing through a machine with ...

    Text Solution

    |

  8. Transformers are used

    Text Solution

    |

  9. The magnitude of the e.m.f. across the secondary of a transformer does...

    Text Solution

    |

  10. For an ideal transformer ratio of output ot the input power is always

    Text Solution

    |

  11. Consider the following two statements A and B and identify the correct...

    Text Solution

    |

  12. Statement (A) : Flux leakage in a transformer can be minimized by wind...

    Text Solution

    |

  13. Statement (A) : In high current low voltage windings of a transformer ...

    Text Solution

    |

  14. Statement (A) : Step up transformer converts low voltage, high current...

    Text Solution

    |

  15. To reduce the iron losses in a transformer, the core must be made of a...

    Text Solution

    |

  16. Maximum efficiency of a transformer depends on

    Text Solution

    |

  17. For an LCR series circuit with an aac source of angular frequency omeg...

    Text Solution

    |

  18. The value of current in tow series LCR circuits at resonance is same, ...

    Text Solution

    |

  19. When an ac source of emfe=E(0) sin (100 t) is connected across a circu...

    Text Solution

    |

  20. An AC voltage source of variable angular frequency (omega) and fixed a...

    Text Solution

    |