Home
Class 11
PHYSICS
What is vernier constant?...

What is vernier constant?

A

It is the value of the one main scale division by the total number of divisions on the main scale

B

It is the value of one vernier scale division divided by the total number of division on the vernier scale

C

It is the difference between value of one main scale division and one vernier scale division

D

It is not the least count of vernier scale

Text Solution

Verified by Experts

The correct Answer is:
C

1 MSD - 1 VSD = Vernier Constant
Promotional Banner

Topper's Solved these Questions

  • ERROR AND MEASUREMENT

    ALLEN|Exercise Part-2(Exercise-2)(A)|16 Videos
  • ERROR AND MEASUREMENT

    ALLEN|Exercise Part-2(Exercise-2)(B)|22 Videos
  • ERROR AND MEASUREMENT

    ALLEN|Exercise Part-2(Exercise-2)(B)|22 Videos
  • ELASTICITY, SURFACE TENSION AND FLUID MECHANICS

    ALLEN|Exercise Exercise 5 B (Integer Type Questions)|3 Videos
  • KINEMATICS

    ALLEN|Exercise Integer Type Question|3 Videos

Similar Questions

Explore conceptually related problems

The thin metallic strip of vernier callipers moves downward from top to botton in such a way that it just touches the surface of beaker. Main scale reading of calliper is 6.4 cm whereas its vernier constant is 0.1 mm. The 4^(th) of vernier scale division is coinciding with main scale division. The actual depth of berker in mm is (when zero of vernier coincides with zero of main scale)

In a vernier callipers, ten smallest divisions of the vernier scale are equal to nine smallest division on the main scale. If the smallest division on the main scale is half millimeter, then the vernier constant is

Each division on the main scale is 1 mm . Which of the following vernier scales give vernier constant equal to 0.01 mm ?

Length of one division of main scale of a vernier calliper is 0.1 cm and that of scale is 0.9 cm. Find the value of vernier constant.

Vernier constant is the

When the two jaws of a vernier callipers are in touch, zero of vernier scale lies to the right of zero of main scale and coinciding with vernier division 3 . If vernier constant is 0.1 mm , the zero correction is

The vernier constant of a vernier callipers is 0.001 cm . If 49 main scale divisions coincide with 50 vernier scale devisions, then the value of 1 main scale divisions is .

The side of a cubical block when measured with a vernier callipers is 2.50 cm. The vernier constant is 0.01 cm. The maximum possible error in the area of the side of the block is

In a slide callipers, (m +1) number of vernier divisions is equal to m number of smallest main scale divisions. If d unit is the magnitude of the smallest main scale division, then the magnitude of the vernier constant is .

ALLEN-ERROR AND MEASUREMENT-Part-2(Exercise-1)
  1. The least count of a stop watch is 0.2 s, The time of 20 oscillations ...

    Text Solution

    |

  2. The area of a rectangle of size 1.23 xx 2.345 cm is

    Text Solution

    |

  3. What is vernier constant?

    Text Solution

    |

  4. The vernier of a circular scale is divided into 30 divisons, which coi...

    Text Solution

    |

  5. What is the reading of micrometer screw gauge shown in figure

    Text Solution

    |

  6. In a vernier calliper, N divisions of vernier scale coincide with (N-1...

    Text Solution

    |

  7. A vernier callipers having 1 main scale division = 0.1 cm to have a le...

    Text Solution

    |

  8. In a vernier callipers, N divisions of the main scale coincide with N ...

    Text Solution

    |

  9. In a vernier callipers the main scale and the vernier scale are made u...

    Text Solution

    |

  10. Consider the MB shown in the diagram, let the resistance X have temper...

    Text Solution

    |

  11. For a post office box, the graph of galvanometer deflection versus (R ...

    Text Solution

    |

  12. Identify which of the following diagrams represent the internal constr...

    Text Solution

    |

  13. In a meter bridge set up, which of the following should be the propert...

    Text Solution

    |

  14. The relative error in resistivity of a material where resistance = 1...

    Text Solution

    |

  15. In the searle's experiment, after every step of loading, why should we...

    Text Solution

    |

  16. Internal micrometer is a measuring intrument used to measure internal ...

    Text Solution

    |

  17. Internal micrometer is a measuring intrument used to measure internal ...

    Text Solution

    |

  18. Internal micrometer is a measuring intrument used to measure internal ...

    Text Solution

    |

  19. In a given slide callipers 10 division of its vernier coincides with i...

    Text Solution

    |

  20. Consider a home made vernier scale as shown in the figure. In this dia...

    Text Solution

    |