Home
Class 12
PHYSICS
Statement-1 If the accelerating potent...

Statement-1
If the accelerating potential in an X-ray tube is increased, the wavelength of the characterstic X-rays do not change.
because
Statement-2
When an electron beam strikes the target in an X-ray tube, part of the kinetic energy is converted into X-ray energy.

A

Statement-1 is true, statement-2 is true and statement-2 is correct explanation for statement-1.

B

Statement-1 is true, statement-2 is true and statement-2 is not the correct explanation for statement-1

C

Statement-1 is true, statement-2 is false

D

Statement-1 is false, statement-2 is true.

Text Solution

Verified by Experts

The correct Answer is:
B
Promotional Banner

Topper's Solved these Questions

  • IIT QUESTIONS 2

    D MUKHERJEE|Exercise Linked -comprehension type|3 Videos
  • IIT QUESTIONS 2

    D MUKHERJEE|Exercise Matrix matching type|1 Videos
  • IIT QUESTIONS 2

    D MUKHERJEE|Exercise Matrix matching type|1 Videos
  • IIT QUESTIONS 1

    D MUKHERJEE|Exercise Matrix-Matching Type|1 Videos
  • IIT QUESTIONS 3

    D MUKHERJEE|Exercise Matrix matching type|1 Videos

Similar Questions

Explore conceptually related problems

STATEMENT - 1 If the accelerating potential in an X - rays tube is increased, the wavelength of the characteristic X- rays do not change . STATEMENT -2 When an electron beam strikes the target in an X- rays tube, part of the kinectic energy is converted into X - rays energy .

For a given material, the energy and wavelength of characterstic X-rays satisfy

The operating potential in an x-ray tube is increased by 2%. The percentage change in the cut off wavelength is

The characteristic of the electrons striking the target in an X-ray tube that, determines the intensity of X-rays is

In X -rays tube the accelerating potential at the anode is V volt, The minimum wavelength of the emitted X -rays will be.

Statement I: In an X-ray tube , if the energy with which an electron strickes the metal target increases , then the wavelength of the characteristic X-rays also changes. Statement II : Wavelength of the characteristic X-rays depends only on the initial and final energy levels.

The kinetic energy of electrons that strike the target is increased , then the cut-off wavelength of continuous X-rays spectrum

In an X-ray tube, the intensity of the emitted X-ray beam is increased by

A: If the accelerating potential in an X- ray machine is decreased, the minimum value of the wavelength of the emitted X -rays gets increased. R: The minimum value of wavelength of the emitted X-rays is inversely proportional to the accelerating potential.

STATEMENT-1: In an X-ray tube, the wavelengths of the characteristic X-rays depends on the metal used as target. STATEMENT-2: Metals atomic numbers are best suited for the production of X-rays