Home
Class 12
PHYSICS
A step - dwon transfermer is desiged to ...

A step - dwon transfermer is desiged to step down the power line voltage of 2200 V, 50 Hz to 220 V for distribuation to domestic Calculate the primary currect when the transformer delivers power to a load to only `2.4 Omega ` assuming it on to be an ideal one .What is its transformation radio?

Promotional Banner

Topper's Solved these Questions

  • DYNAMO, MOTOR, TRANSFORMER

    NN GHOSH|Exercise EXERCISE|8 Videos
  • DISPERSION

    NN GHOSH|Exercise Exercises|7 Videos
  • ELECTRIC FIELD AND POTENIAL

    NN GHOSH|Exercise EXERCISE-B|35 Videos

Similar Questions

Explore conceptually related problems

A transformer is used to step down mains supply of 220 V to 22 V. Its primary draws a current of 6 A and secondary draws a current of 50 A . Calculate the efficiency of the transformer .

An ideal transformer is used to step up an alternating emf of 220V to 4.4kV to transmit 6.6kW of power The current rating of the secondary is

A step down transformer of efficiency 80% is used on a 1000V line to deliver a current of 20 A at 120 V at the secondary coil. What is the current drawn from the line?

A step-down transfomer reduces the voltage of a transmission line from 2200 V to 220 V. the power delivered by it is 880 W and its efficiency is 88%. The input current is

A thermal power plant produed electric power of 600kW at 4000V, which is to be transported to a place 20 km away form the power plant for consumer's usage. It can be transported either directly with a cable of large current carrying capacity or by sing a combination of step-up and step-down transfprmers at the two ends. THe drawback of the direct transmission is the large energy dissipation. In the method wsing transformers, the dissipatiion is much smaller. In this method a step-up transformers is used at the plant side so that the current is reduced to a smaller value. At the consumers'end, a step-down transformer is used to supply power to the consumers at the specified lower voltage. It is reasonable to assume that the power cable is purely resostive and the transformers are ideal with power factor unity. All the currents and voltagementioned are values. If hte direct transmission method with a cable of resistance 0.4(omega) km^(-1) is used, the power dissipation (in %) during transmission is

A step down transformer converts transmission line voltage from 11000 V to 220 V. The primary of the transformer has 6000 turns and efficiency of the transformer is 60%. If the output power is 9 kW, then the input power will be

A power transformer is used to step up an alternating emf of 200V to 4 KV and to transmits 5KW power. If the primary is of 1000 turns, calculate, assuming the transformer to be ideal. (i) The number of turns in the secondary (ii) The current rating of the secondary