A step down transformer converts transmission line voltage from 2200 V to 220 V. Primary coil is having 5000 turns. Efficiency of transformer is 90% and output power is 8 kW. Evaluate number of turns in secondary coil and input power.

Promotional Banner

Topper's Solved these Questions

  • AC CIRCUITS AND ELECTRIC CIRCUITS

    SL ARORA|Exercise problem|57 Videos
  • ATOMS, NUCLEI AND MOLECULES

    SL ARORA|Exercise Problems For Self Practice|87 Videos

Similar Questions

Explore conceptually related problems

A step down transformer converts transmission line voltage from 11000 V to 220 V. The primary of the transformer has 6000 turns and efficiency of the transformer is 60%. If the output power is 9 kW, then the input power will be

A step down transformer converts a voltage of 2000 V inot 200 V in the transmission line. Number of turns in primary coil is 5000, efficiency of transformer is 80% and output power is 8 kW. Calculate input power and number of turns in secondary coil.

A step-down transfomer reduces the voltage of a transmission line from 2200 V to 220 V. the power delivered by it is 880 W and its efficiency is 88%. The input current is

The number of turns in secondary coil of a transformer is 100 times the number of turns in primary coil. What is the transformer ratio ?

A transformer has 100 turns in the primary coil and carries 8A current. If input power is one kilowatt, the number of turns required in the secondary coil to have 500V output will be

A power transmission line feeds input power at 2400 V to a step down transformer with its primary windings having 4000 turns. What should be the number of turns in the secondary windings in order to get output power at 240 V?

A power transmission line feeds input power at 2300 V to a step down trnasformer with it primary windings having 4000 turns. What should be the number of turns in the seconday windings in order to get output power at 230 V?

A power transmission line feeds input power at 2400V to a step-down transformer and which delivers power at 240V with its primary windings having 5000 turns . If the current in the primary coil of the transformer is 5A and its efficiency is 80%, then what is the output current (in A)?

SL ARORA-AC CIRCUITS AND ELECTRIC CIRCUITS-problem
  1. An a,c, source of frequency 50 hertz is connected to a 50 mH inductor ...

    Text Solution

    |

  2. A 200km long telegraph wire has capacitance of 0.014 mu F//km If it ca...

    Text Solution

    |

  3. Fig 14.18 shows a series LCR circuit connected to a variable frequency...

    Text Solution

    |

  4. A 100 mH inductor, a 20 muF capacitor and a 10 ohm resistor are connec...

    Text Solution

    |

  5. Compute the resonant frequency and the Q factor of a series LCR circui...

    Text Solution

    |

  6. In the circuit shown in fig. potential diff. across L, C and and R are...

    Text Solution

    |

  7. A 60 cycle AC circuit has a resistance of 200 Omega and inductance of ...

    Text Solution

    |

  8. A transformer has 300 primary turns and 2400 secondary turns: If the p...

    Text Solution

    |

  9. A transformer has 200 primary turns and 150 secondary turns. If the op...

    Text Solution

    |

  10. The turns ratio of a transformer is 12.5. If its primary is connected ...

    Text Solution

    |

  11. A step-up transfomer operates on a 220 volt line and supplies to load,...

    Text Solution

    |

  12. In a stepup transformer, the ratio of number of turns in primary and s...

    Text Solution

    |

  13. Calculate current drawn by primary coil of a transformer, Which steps ...

    Text Solution

    |

  14. The output voltage of an ideal transformer, connected to a 240 V ac. w...

    Text Solution

    |

  15. A step down transformer is used at 220 V to provide a current of 0.5 A...

    Text Solution

    |

  16. A step down transformer converts transmission line voltage from 2200 V...

    Text Solution

    |

  17. The number of turns in the primary and secondary coils of an ideal tra...

    Text Solution

    |

  18. The primary of a transformer has 200 turns and secondary has 1000 turn...

    Text Solution

    |

  19. An a.c generator consists of a coil of 50 turns and area 2.5 m^(2) rot...

    Text Solution

    |

  20. A generator develops an e.m.f. of 120 V and has a terminal potential d...

    Text Solution

    |