A single ended class A transformer coupled amplifier delivers a power of 50 mW, `V_(cc)` = 10 volts. Assuming ideal conditions, the reflected primary resistance is given by

A

`2000 Omega`

B

`1000 Omega`

C

`500 Omega`

D

`200 Omega`

Text Solution

Verified by Experts

The correct Answer is:
B

For ideal condition, `P=(V^(2))/(R+R)`
`2R=(10 xx10)/(50 xx 10^(-3)=2000`
`R= 1000Omega`
Promotional Banner

Topper's Solved these Questions

  • SEMICONDUCTOR DEVICES AND LOGIC GATES

    BITSAT GUIDE|Exercise BITSAT Archives|5 Videos
  • RAY OPTICS

    BITSAT GUIDE|Exercise All Questions|39 Videos
  • SOLVED PAPER 2017

    BITSAT GUIDE|Exercise (PART -I) PHYSICS |40 Videos

Similar Questions

Explore conceptually related problems

A step - dwon transfermer is desiged to step down the power line voltage of 2200 V, 50 Hz to 220 V for distribuation to domestic Calculate the primary currect when the transformer delivers power to a load to only 2.4 Omega assuming it on to be an ideal one .What is its transformation radio?

A thermal power plant produed electric power of 600kW at 4000V, which is to be transported to a place 20 km away form the power plant for consumer's usage. It can be transported either directly with a cable of large current carrying capacity or by sing a combination of step-up and step-down transfprmers at the two ends. THe drawback of the direct transmission is the large energy dissipation. In the method wsing transformers, the dissipatiion is much smaller. In this method a step-up transformers is used at the plant side so that the current is reduced to a smaller value. At the consumers'end, a step-down transformer is used to supply power to the consumers at the specified lower voltage. It is reasonable to assume that the power cable is purely resostive and the transformers are ideal with power factor unity. All the currents and voltagementioned are values. In the method using the transformers assume that the ratio of the number of turns in the primary to that in the secondary in the step-up transformer is 1:10 if the power to the consumers has to be supplied at 200V, the ratio of the number of turns in the primary to that in the secondary in the step-down transformer is

A thermal power plant produed electric power of 600kW at 4000V, which is to be transported to a place 20 km away form the power plant for consumer's usage. It can be transported either directly with a cable of large current carrying capacity or by sing a combination of step-up and step-down transfprmers at the two ends. THe drawback of the direct transmission is the large energy dissipation. In the method wsing transformers, the dissipatiion is much smaller. In this method a step-up transformers is used at the plant side so that the current is reduced to a smaller value. At the consumers'end, a step-down transformer is used to supply power to the consumers at the specified lower voltage. It is reasonable to assume that the power cable is purely resostive and the transformers are ideal with power factor unity. All the currents and voltagementioned are values. If hte direct transmission method with a cable of resistance 0.4(omega) km^(-1) is used, the power dissipation (in %) during transmission is