Home
Class 12
PHYSICS
A town situated 20 kW away from a power ...

A town situated 20 kW away from a power plant generating power at 440 V requires 600 KW of electric power at 200 V. The resistance of two wire lines carrying poweris `0.4 Omega` per km. The town gets power from the line through a 3000-220 V step down transformer at a substation in the town. Find line power losses in the form of heat. How much power must the plant supply assuming that there is negligilbe power loss due to leakage ?

A

The loss in the form of heat is `640 KW`

B

The loss in the form of heat is `1240 kW`

C

Plant should supply `1240 kW`

D

Plant should supply `640 kW`

Text Solution

Verified by Experts

The correct Answer is:
A,C
Promotional Banner

Topper's Solved these Questions

  • ALTERNATING CURRENT

    RESONANCE|Exercise Exercise -2 Part-4|11 Videos
  • ALTERNATING CURRENT

    RESONANCE|Exercise Exercise -3 Part-1|7 Videos
  • ALTERNATING CURRENT

    RESONANCE|Exercise Exercise -2 Part-2|6 Videos
  • ATOMIC PHYSICS

    RESONANCE|Exercise Advanved level problems|17 Videos

Similar Questions

Explore conceptually related problems

A small town with a demand of 800 kW of electric power at 220 V is situated 15 km away from an electric plant generating power at 440 V. The resistance of the two line wires carrying power is 0.5 Omega per km. The town gets power from the lines through a 4000-220 V step down transformer at a substation in the town. Estimate the line power loss in the form of heat. (b) How much power must the plant supply. assuming there is negligible power loss due to leakage? (c) Characterize the step up transformer at the plant.

(a) Draw the diagram of a device which is used to decrease high S voltage into a AC voltage and state its working principle. Write four sources of energy loss in this device. (b) A small town with a demand of 1200 kW of electric power at 220 V is situated 20 Km away from an electric plant generating power at 440V. The resistance of the two wire line carrying power is 0.5 Omega per km. The town gets the power from the line through a 4000-220 V step-down transformer at s sub-station in the town. Estimate the line power loss in the from of heat.

A village with a demand of 800 kW electric power at 220 V is located 30 km from an electric plant generating power at 440 V. The resistance of the two wire line carrying power is 0.25 Omega /km. The village gets power from the line through a 4000 V – 220 V step down transformer at a sub-station in the village. Assume negligible power loss in the transformers (a) Estimate the power loss in form of heat in the transmission line. (b) How much power must the plant supply? (c) What is the input and output voltage of step-up transformer at the plant ? (d) What difference will it make if the village receives power through a 40,000 V – 220 V step down transformer

A small town with a demand of 1 MW at 220 V is situated 20 km away from an electric plant generating power at 440 V. The resistance of two line wires carrying is 0.5 Omega per km. Two step down transformers are available : 4000 V - 220 V and 100000 V - 220 V at a substationin the town for supply of power. Which one will you prefer and why?