Home
Class 11
PHYSICS
In a meter bridge set up, which of the f...

In a meter bridge set up, which of the following should be the properties of the one meter long wire?

A

High resistivity and low temperature and low temperature coefficient.

B

Low resistivity and low temperature coefficient.

C

Low resistivity and high temperature coefficient.

D

High resistivity and high temperature coefficient.

Text Solution

AI Generated Solution

The correct Answer is:
To determine the properties of the one-meter-long wire in a meter bridge setup, let's analyze the requirements step by step: ### Step 1: Understand the Purpose of the Wire The wire in a meter bridge is used to compare the resistances of two unknown resistors. It should provide a stable and accurate measurement. **Hint:** Consider the role of the wire in ensuring accurate resistance measurements. ### Step 2: Consider Resistivity The wire should have a **high resistivity**. This is because a high resistivity wire will allow for a more significant voltage drop across the wire, making it easier to detect the null point when balancing the bridge. **Hint:** Think about how resistivity affects the voltage drop across the wire. ### Step 3: Evaluate Temperature Coefficient The wire should have a **low temperature coefficient**. This means that its resistance should not change significantly with temperature variations. A low temperature coefficient ensures that the resistance remains stable, which is crucial for accurate measurements. **Hint:** Reflect on how temperature changes can affect resistance and the importance of stability in measurements. ### Step 4: Combine the Properties Based on the analysis, the ideal properties for the one-meter-long wire in a meter bridge setup are: - **High resistivity** - **Low temperature coefficient** ### Conclusion Therefore, the correct option is **A: High resistivity and low temperature coefficient**. ---
Promotional Banner

Topper's Solved these Questions

  • EXPERIMENTS

    DC PANDEY ENGLISH|Exercise Subjective|15 Videos
  • EXPERIMENTS

    DC PANDEY ENGLISH|Exercise Exercise 3.8|3 Videos
  • ELECTROSTATICS

    DC PANDEY ENGLISH|Exercise Integer|17 Videos
  • FLUID MECHANICS

    DC PANDEY ENGLISH|Exercise Medical entranes gallery|49 Videos

Similar Questions

Explore conceptually related problems

Which one of the following is a property of physisorption ?

Which one of the following is not an intensive property?

Which one of the following properties is not shown by NO ? .

In thermodynamics, which one of the following properties is not an intensive property?

Shown in the figure below is a meter- bridge set up will null deflection in the galvanometer. The value of the unknown resistor R is

In the meter bridge experimental set up, shown in the figure, the null point 'D' is obtained at a distance of 40 cm from end A of the meter bridge wire. If a resistance of 10 Omega is connected in series with R_(1), null point is obtained at AD = 60 cm. Calculate the values of R_(1) and R_(2).

Which one of the following electrical meter has the smallest resistance ?

A meter bridge setup is shown in the figure. If there is null deflection in galvanometer when length AC = 20 cm, then the value of resistance R is

STATEMENT-1 : In a meter bridge, if its wire is replaced by another wire having same length, same material but twice the cross sectional area, then the accuracy of measurement decreases. and STATEMENT-2 : Accuracy of meter bridge depends on the length of wire.

DC PANDEY ENGLISH-EXPERIMENTS-Single Correct
  1. Select the incorrect statement.

    Text Solution

    |

  2. In the searle's experiment, after every step of loading, why should we...

    Text Solution

    |

  3. In a meter bridge set up, which of the following should be the propert...

    Text Solution

    |

  4. The mass of a copper calorimeter is 40 g and its specific heat in (SI)...

    Text Solution

    |

  5. A graph is drawn with (1)/(u) along x-axis and (1)/(v) along the y-axi...

    Text Solution

    |

  6. For a post office box, the graph of galvanometer deflection verus (R )...

    Text Solution

    |

  7. 1 cm on the main scale of a vernier calipers is divided into 10 equal ...

    Text Solution

    |

  8. The vernier constant of a vernier calipers is 0.001 cm. If 49 main sca...

    Text Solution

    |

  9. 1 cm of main scale of a vernier callipers is divided into 10 divisions...

    Text Solution

    |

  10. Each division on the main scale is 1 mm. Which of the following vernie...

    Text Solution

    |

  11. A vernier calipers having 1 main scale division = 0.1 cm to have a lea...

    Text Solution

    |

  12. The length of a rectangular plate is measured by a meter scale and is ...

    Text Solution

    |

  13. In the previous question, minimum possible error in area measurement c...

    Text Solution

    |

  14. The distance moved by the screw of a screw gauge is 2 mm in four rotat...

    Text Solution

    |

  15. The end correction ( e) is (l(1) = length of air column at first reson...

    Text Solution

    |

  16. The end correction of a resonance tube is 1 cm. If shortest resonating...

    Text Solution

    |

  17. A tuning fork of frequency 340 Hz is excited and held above a cylindri...

    Text Solution

    |

  18. Two unknown frequency tuning forks are used in resonance column appara...

    Text Solution

    |

  19. In an experiment to determine the specific heat of aluminium, piece of...

    Text Solution

    |

  20. When 0.2 kg of brass at 100 .^(@) C is dropped into 0.5 kg of water at...

    Text Solution

    |