Home
Class 12
PHYSICS
A straight solenoid has 50 turns per cm ...

A straight solenoid has 50 turns per cm in primary and total 200 turns in the secondary. The area of cross section of the solenoids is `4cm^2`. Calculate the mutual inductance. Primary is tightly kept in side the secondary.

Text Solution

AI Generated Solution

To calculate the mutual inductance \( M \) of the solenoids, we can use the formula: \[ M = \frac{N_2 \Phi}{I_1} \] where: - \( N_2 \) is the number of turns in the secondary coil, ...
Doubtnut Promotions Banner Mobile Dark
|

Topper's Solved these Questions

  • ELECTROMAGNETIC INDUCTION

    DC PANDEY ENGLISH|Exercise Check point|60 Videos
  • ELECTROMAGNETIC INDUCTION

    DC PANDEY ENGLISH|Exercise Taking it together|119 Videos
  • ELECTROMAGNETIC INDUCTION

    DC PANDEY ENGLISH|Exercise Level 2 Subjective|20 Videos
  • CURRENT ELECTRICITY

    DC PANDEY ENGLISH|Exercise Medical entrances gallery|97 Videos
  • ELECTROMAGNETIC WAVES

    DC PANDEY ENGLISH|Exercise Sec C|22 Videos

Similar Questions

Explore conceptually related problems

A straight solenoid of length 1 m has 5000 turns in the primary and 200 turns in the secondary. If the area of cross section is 4 cm^(2) , the mutual inductance will be

A transformer has 500 turns in its primary and 1000 turns in its secondary winding. The primary voltage is 200 V and the load in the secondary is 100 2. Calculate the current in the primary, assuming it to be an ideal transformer.

A solenoid is of length 50 cm and has a radius of 2cm. It has 500 turns. Around its central section a coil of 50 turns is wound. Calculate the mutual inductance of the system.

A transformer has 1500 turns in the primary coil and 1125 turns in the secondary coil. If a voltage of 200V is applied across the primary coil , then the voltage in the secondary coil is :

Two toroidal solenoids are wound around the same pipe so that the magnetic field of one passes through the turns of the other. Solenoid 1 has 700 turns and solenoid 2 has 400 turns. When the current in solenoid 1 is 6.52 A , the average flux through each turn of solenoid 2 is 0.0320 Wb . (a) What is the mutual inductance of the pair of solenoids? (b) When the current in solenoid 2 is 2.54 A , what is the average flux through each solenoid 1?

A transformer has 50 turns in the primary and 100 in the secondary. If the primary is connected to a 220 V DC supply, what will be the voltage across the secondary?

A transformer has 50 turns in the primary and 100 in the secondary. If the primary is connected to a 220 V DC supply, what will be the voltage across the secondary?

A transformer of 100 % efficiency has 200 turns in the primary and 40,000 turns in the secondary. It is connected to a 220 V a.c. mains and the secondary feeds to a 100 k Omega resistance. Calculate the output potential difference per turn and the power delivered to the load.

A solenoid of length 50cm with 20 turns per centimetre and area of cross-section 40cm? completely surrounds another coaxial solenoid of the same length, area of cross-section 25cm^(2) with 25 turns per centimetre. Calculate the mutual inductance of the system.

Over a solenoid of 50cm length and 2cm radius and having 500turns is would another wire of 50 turns near the centre. Calculate (i) mutual inductance of the two coils (ii) Induced emf in the second coil when the current in the primary changes from 0 to 5A in 0.02 sec.