Home
Class 12
PHYSICS
Resistance of platinum wire in a platinu...

Resistance of platinum wire in a platinum resistance thermometer at melting ice, boiling water and at a hot bath are `5 Omega , 5.5 Omega` and `5.2 Omega ` respectively . Find temperature of hot bath.

Text Solution

Verified by Experts

Omegat`R_(0)= 5 Omega , R_(100)= 5.5 Omega , R_(t ) = = 5.2 Omega `
`t = ( R_(t) - R_(0))/( R_(100)-R_(0))xx 100 ^(@) C = ( 5.2 - 5)/( 5.5 -5) xx 100^(@) C `
`= ( 0.2 )/( 0.5) xx 100^(@) C = 40^(@) C `
Promotional Banner

Topper's Solved these Questions

  • CURRENT ELECTRICITY

    AAKASH INSTITUTE ENGLISH|Exercise Try Yourself|34 Videos
  • CURRENT ELECTRICITY

    AAKASH INSTITUTE ENGLISH|Exercise ASSIGNMENT(SECTION-A(OBJECTIVE TYPE QUESTIONS))|69 Videos
  • COMMUNICATION SYSTEMS

    AAKASH INSTITUTE ENGLISH|Exercise ASSIGNMENT SECTION D (Assertion-Reason)|10 Videos
  • DUAL NATURE OF RADIATION AND MATTER

    AAKASH INSTITUTE ENGLISH|Exercise ASSIGNMENT (SECTION-D)|10 Videos

Similar Questions

Explore conceptually related problems

Resistance of platinum wire in a platinum resistance thermometer at melting ice, boiling water and at a hot bath are 6Omega,6.5Omega and 6.2Omega , respectively. Find temperature of hot bath.

In a platinum resistance thermometer resitance of the platinum wire at 0^(@)C, 100^(@) C and in hot bath are 8 Omega , 12 Omega and 11 Omega respectively. Temperature of hot bath is

The resistances of a platinum resistance thermometer at the ice point, the steam point and the boiling point of sulphur are 2.50, 3.50 and 6.50 Omega respectively. Find the boiling point of sulphur on the platinum scale. The ice point and the steam point measure 0^0 and 100^0 respectively.

The resistances of a platinum resistance thermometer at the ice point, the steam point and the boiling point of sulphur are 2.50, 3.50 and 6.50 (Omega) respectively. Find the boiling point of sulphur on the platinum scale. The ice point and the steam point measure 0^@ and 100^@ , respectively.

The resistance of a platinum wire of platinum resistance thermometer at the ice point is 5 Omega and at steam point is 5.23 Omega . When therometer is insertes in a hot bath, the resistance of the platinum wire is 5.795 Omega . Calculate the temperature of the bath?

The resistance of the wire in the platinum resistance thermometer at ice point is 5Omega and at steam point is 5.25Omega . When the thermometer is inserted in an unknown hot bath its resistance is found to be 5.5Omega . The temperature of the hot bath is

The total resistance in the parallel combination of three resistances 9Omega, 7Omega and 5Omega

When a constant volume gas thermometer is placed in melting ice, boiling water and in an unknown hot bath, the pressure of the gas at constant volume are found to be 1m,1.3m and 1.8m of Hg respectively. Calculate the unknown temperature.

The following observation were recorded on a platinum resistance thermometer. Resistance at melting point of ice is =3.70 Omega, resistance at boiling point of water at normal pressure is =4.71 Omega, and resistance at t^(@)C=5.29Omega. Calculate Temperature coefficient of resistance of platinum. Value of temperature t.

A platinum resistance thermometer reads 0^@ C when its resistance is 80 Omega and 100^@ C when its resistance is 90 Omega . Find the temperature at which the resistance is 86 Omega .