(i) Galvanometer resistance `G = ("Full scale voltage")/("Full scale current")`
(ii) Fule scale voltage `=("No of division")/("voltage sensitivity")= (150)/(2)= 75V `
(ii) Full scale current `=("No. of divisions")/("current sensitivity ")= (15)/(10) =15mA `
(iv) `:. G= ( 75)/(15) = 5Omega `
(v) `S = (i_(g)G)/(i-i_(g))= ( 15 xx 10^(-3)xx5)/( 150 xx 6- 15 xx 10^(-3))= 8.3 xx 10^(-5) Omega`
(vi) `R= (V)/(i_(g))-G= ( 150)/(15xx10^(-3))-5 = 9995Omega`
Promotional Banner

Topper's Solved these Questions

  • CURRENT ELECTRICITY

    AAKASH INSTITUTE ENGLISH|Exercise Try Yourself|34 Videos
  • CURRENT ELECTRICITY

    AAKASH INSTITUTE ENGLISH|Exercise ASSIGNMENT(SECTION-A(OBJECTIVE TYPE QUESTIONS))|69 Videos
  • COMMUNICATION SYSTEMS

    AAKASH INSTITUTE ENGLISH|Exercise ASSIGNMENT SECTION D (Assertion-Reason)|10 Videos
  • DUAL NATURE OF RADIATION AND MATTER

    AAKASH INSTITUTE ENGLISH|Exercise ASSIGNMENT (SECTION-D)|10 Videos

Similar Questions

Explore conceptually related problems

A galvanometer with a scale divided into 100 equal divisions has a current sensitivity of 10 divisions per mA and a voltage sensitivity of 2 divisions per mV. What adoptions are required to read (i) 5A for full scale and (ii) 1 division per volt?

A moving coil galvanometer has 150 equal divisions. Its current sensitivity is 10-divisions per milliampere and voltage sensitivity is 2 divisions per millivolt. In order that each division reads 1 volt, the resistance in ohms needed to be connected in series with the coil will be -

A galvanometer having 30 divisions has current sensitivity of 20 mu A//"division" . Find the maximum current it can measure.

A galvanometer having 30 divisions has current sensitivity of 20 mu A//"division" . Find the maximum current it can measure.

The sensitivity of a galvanometer is 60 divisions/Amp. When a shunt is used, its sensitivity becomes 10 divisions/amp. If galvanometer is of resistance 20Omega , · the value of shunt used is :

1 cm of main scale of a vernier callipers is divided into 10 divisions. The least count of the callipers is 0.005 cm , then the vernier scale must have.

1 cm of main scale of a vernier callipers is divided into 10 divisions. The least count of the callipers is 0.005 cm , then the vernier scale must have.

1 cm on the main scale of a vernier calipers is divided into 10 equal parts. If 10 divisions of vernier coincide with 8 small divisions of main scale, then the least count of the caliper is.

1 cm on the main scale of a vernier callipers is divided into 10 equal parts. If 10 divisions of vernier coincide with 8 small divisions of main scale, then the least count of the calliper is.

A galvanometer with a coil of resistance 100 Omega and a scale having 100 divisions has a current sensitivity of 25 muA//"division." How will you convert it into an ammeter of range 0 to 5 A?