What is the resistance, under normal working conditions, of an electric lamp rated 240 V, 60 W'? If two such lamps are connected in series across a 240 V mains supply, explain why each one appears less bright.

Text Solution

AI Generated Solution

To solve the problem, we will follow these steps: ### Step 1: Calculate the Resistance of One Lamp We know the power (P) and voltage (V) ratings of the lamp: - Voltage (V) = 240 V - Power (P) = 60 W Using the formula for power: ...
Promotional Banner

Topper's Solved these Questions

  • CURRENT ELECTRICITY

    ICSE|Exercise EXERCISE-8(C) MULTIPLE CHOICE TYPE)|2 Videos
  • CALORIMETRY

    ICSE|Exercise EXERCISE-11(B) (NUMERICALS)|15 Videos
  • ELECTRO-MAGNETISM

    ICSE|Exercise EXERCISE-10 (C) NUMERICALS |1 Videos

Similar Questions

Explore conceptually related problems

Three bulbs of 40 W , 60 W and 100 W are connected in series with a 240 V source.

If two bulbs of 25 W and 100 W rated at 220 V are connected in series across a 440 V supply, will both the bulbs fuse ? If not which one ?

Two identical electric lamps marked 500 W , 220 V are connected in series and then joined to a 110 V line. The power consumed by each lamp is

Two electric bulbs one, if 200 V-40 W and other 200 V-100 W are connected in series to a 200 V line, then the potential drop across

Two electric bulbs rated P_(1) and P_(2) watt at V volt are connected in series across V volt mains then their total power consumption P is

When three identical bulbs of 60 W, 200 V rating are connected in series to a 200 V supply, the power drawn by them will be

Two bulbs of rated power 60W and 100W same specified voltage 220 V are connected in series to a 440 V DC source

An electric bulb rated '220 V, 60 W' glows when connected with 220 V mains. Find the resistance of the filament of the bulb.

Two bulbs 60 W and 100 W designed for voltage 220 V are connected in series across 220 V source. The net power dissipated is

Two electric lamps are rated as 220V. 40 W and 220V,60W. Find the heat generated per second in lamp when they are connected in series across 220V mains. Given 1 cal=4.2J.

ICSE-CURRENT ELECTRICITY-EXERCISE-8(C) NUMERICALS
  1. A current of 0.2 A flows through a wire whose ends are at a potential ...

    Text Solution

    |

  2. A current of 0.2 A flows through a wire whose ends are at a potential ...

    Text Solution

    |

  3. What is the resistance, under normal working conditions, of an electri...

    Text Solution

    |

  4. Two bulbs are rated 60 W, 220 V' and '60 W, 110 V respectively. Calcul...

    Text Solution

    |

  5. An electric bulb is rated 250 W, 230 V'. Calculate: the energy con...

    Text Solution

    |

  6. An electric bulb is rated 250 W, 230 V'. Calculate: the time in wh...

    Text Solution

    |

  7. Three heaters each rated *250 W, 100 V are connected in parallel to a ...

    Text Solution

    |

  8. Three heaters each rated *250 W, 100 V are connected in parallel to a ...

    Text Solution

    |

  9. Three heaters each rated *250 W, 100 V are connected in parallel to a ...

    Text Solution

    |

  10. A bulb is connected to a battery of p.d. 4 V and internal resistance 2...

    Text Solution

    |

  11. A bulb is connected to a battery of p.d. 4 V and internal resistance 2...

    Text Solution

    |

  12. A bulb is connected to a battery of p.d. 4 V and internal resistance 2...

    Text Solution

    |

  13. Two resistors A and B of resistance 4 Omega and 6 Omega respectively...

    Text Solution

    |

  14. Two resistors A and B of resistance 4 Omega and 6 Omega respectively...

    Text Solution

    |

  15. A battery of e.m.f. 15 V and internal resistance 2 Omega is connecte...

    Text Solution

    |

  16. Water in an electric kettle connected to a 220 V supply takes 5 minute...

    Text Solution

    |

  17. An electric toaster draws current 8 A in a circuit with source of volt...

    Text Solution

    |

  18. An electric iron is rated 220 V, 2 kW. If the iron is used for 3h da...

    Text Solution

    |

  19. An electrical appliance is rated 1500 W, 250 V. This appliance is conn...

    Text Solution

    |

  20. A geyser is rated '1500 W, 250 V'. This geyser is connected to 250 V m...

    Text Solution

    |