Home
Class 12
PHYSICS
A current is induced in coil C1 due to ...

A current is induced in coil `C_1` due to the motion of current carrying coil `C_2`.
(a) Write any two ways by which a large deflection can be obtained in the galvanometer G. (b) Suggest an alternative device to demonstrate the induced current in place of galvanometer.

Text Solution

Verified by Experts

(a)When coil `C_(1)` and `C_(2)` held stationary.Coil `C` is connected to a sensitive galvanometer `G` and coil `C_(2)` is connected to a battery through a trapping ket `K`.
When the key is released the galvanometer shows again a momentary deflection.but in the opposite direction The pointer in the galvometer returns to zero almost instantly.The galvanometer direction increases dramatically when an iron rod is inserted into the coils along their axis.
(b) Ammeter can be used in place Galvanometer to read the current.
Promotional Banner

Topper's Solved these Questions

  • ELECTROMAGNETIC INDUCTION

    RESONANCE ENGLISH|Exercise A.l.P|19 Videos
  • ELECTROMAGNETIC INDUCTION

    RESONANCE ENGLISH|Exercise Exercis-3 PART 2|16 Videos
  • ELECTRODYNAMICS

    RESONANCE ENGLISH|Exercise Advanced level problems|31 Videos
  • ELECTROSTATICS

    RESONANCE ENGLISH|Exercise HLP|40 Videos

Similar Questions

Explore conceptually related problems

A current is induced in coil C_1 due to the motion of current carrying coil C_2 . (a) Write any two ways by which a large deflection can be obtained in the galvanometer G. (b) Suggest an altermative device to demonstrate the induced current in place of galcanometer.

Consider Experiment 2, Art. 4(a). 3, (a) What would you do to obtain a large deflection of the galvanometer ? (b) How would you demonstrate the presence of an induced current in the absence of a galvanmeter ?

The induced emf in a coil of 10 H inductance in which current varies from 9 A to 4 A in 0.2 s is

Energy in a current carrying coils is stored in the form of (a) electric field (b) magnetic field (c) dieclectric strenght (d) heat

Two coils C_(1) and C_(2) are kept coaxially as shown the coil C_(1) is connected to a battery and the coil C_(2) is connected to a galvanometer. The deflection in galvanometer can be increased by

State the underlying principles of working of a moveing coil galvanometer. Write the two reasons why a galvonmeter cannot be used as such to measure current in a given circuit.Name any two factors on which that current sensitivity of a galvanometer depends.

The mutual inductance between two coils is 2.5 H . If the current in one coil is changed at the rate of 1 As^(-1) , what will be the emf induced in the other coil?

A square coil ABCD lying in x-y plane with its centre at origin. A long straight wire passing through origin carries a current i=2t in negative z-direction. The induced current in the coil is

A square coil ABCD lying in x-y plane with its centre at origin. A long straight wire passing through origin carries a current i=2t in negative z-direction. The induced current in the coil is

Two different coils have self inductances L_1=9mH and L_2=2mH . The current in one coil is increased at a constant rate. The current in the second coil is also increased at the same constant rate. At a certain instant of time, the power given to the two coils is the same. At that time, the current the induced voltage and the energy stored in the first coil are i_1,V_1 and W_1 respectively. Corresponding values for the second coil at the same instant are i_2,V-2 and W_2 respectively. Then,