Home
Class 12
PHYSICS
A step-down transfomer reduces the volta...

A step-down transfomer reduces the voltage of a transmission line from 2200 V to 220 V. the power delivered by it is 880 W and its efficiency is 88%. The input current is

A

4.65 mA

B

0.465 A

C

0.4545 A

D

4.65 A

Text Solution

Verified by Experts

The correct Answer is:
C

`eta=P_(S)/P_(P)=(880)/(2200xxi_(p))rArri_(p)=880/(2200xx0.88)=0.454A`.
Promotional Banner

Topper's Solved these Questions

  • ELECTROMAGNETIC INDUCTION

    ERRORLESS|Exercise PAST YEARS QUESTIONS|31 Videos
  • ELECTROMAGNETIC INDUCTION

    ERRORLESS|Exercise ASSERTION & REASON|20 Videos
  • ELECTROMAGNETIC INDUCTION

    ERRORLESS|Exercise NCERT BASED QUESTIONS (STATIC EMI)|39 Videos
  • CURRENT ELECTRICITY

    ERRORLESS|Exercise ASSERTION AND REASON|26 Videos
  • ELECTRON, PHOTON, PHOTOELECTRIC EFFECT & X -RAY

    ERRORLESS|Exercise ASSERTION & REASON|27 Videos

Similar Questions

Explore conceptually related problems

A step down transformer converts transmission line voltage from 11000 V to 220 V. The primary of the transformer has 6000 turns and efficiency of the transformer is 60%. If the output power is 9 kW, then the input power will be

A step down transformer converts transmission line voltage from 2200 V to 220 V. Primary coil is having 5000 turns. Efficiency of transformer is 90% and output power is 8 kW. Evaluate number of turns in secondary coil and input power.

A step down transformer converts a voltage of 2000 V inot 200 V in the transmission line. Number of turns in primary coil is 5000, efficiency of transformer is 80% and output power is 8 kW. Calculate input power and number of turns in secondary coil.

The output voltage of a transformer connected to 220 voltl line is 1100 volt at 1 amp current. Its efficiency is 100% the current coming from the line is

A step down transformer is used to reduce the main supply of 200 V to 11 V. If the primary draws a current of 5 A and the secondary 90 A, what is the efficiency of the transformer ?

A step down transformer works on 220 volts a.c. mains. It is used to light a 100 w, 20 V bulb. The main current is 0.5 A. What is the efficiency of the transformer?

In an ideal transfomer, the voltage is step-down from 11 kV to 220 V. if the primary current be 100 A, the current in the secondary should be

In an ideal transfomer, the voltage is step-down from 11 kV to 220 V. if the primary current be 100 A, the current in the secondary should be

A step-down transformer is used on a 1000 V line to deliver 20A at 120V at the secondary coil. If the efficiency of the transformer is 80% the current drawn from the line is.

ERRORLESS-ELECTROMAGNETIC INDUCTION-NCERT BASED QUESTIONS (APPLICATION OF EMI (Dynamo, Transformer…))
  1. If a coil made of conducting wires is rotated between poles pieces of ...

    Text Solution

    |

  2. An AC generator of 220 V having internal resistance r=10 Omega and ext...

    Text Solution

    |

  3. Voltage in the secondary coil of a transfomer does not depend upon

    Text Solution

    |

  4. In an ideal transformer the number of turns of primary and secondary c...

    Text Solution

    |

  5. A transformer rated at 10 kW is used to connect a 5 kV transmission li...

    Text Solution

    |

  6. The turn ratio of a transformers is given as 2:3. If the current throu...

    Text Solution

    |

  7. The primary winding of a transformer has 100 turns and its secondary w...

    Text Solution

    |

  8. A step up transformer connected to a 220V AC line is to supply 22 kV f...

    Text Solution

    |

  9. The primary winding of transformer has 500 turns whereas its secondary...

    Text Solution

    |

  10. In a step-up transformer the turn ratio is 1:10. A resistance of 200 o...

    Text Solution

    |

  11. In a transformer, number of turns in the primary coil are 140 and that...

    Text Solution

    |

  12. A transformer is used to light a 100 W and 110 V lamp from a 220V main...

    Text Solution

    |

  13. A transformer connected to 220 volt line shows an output of 2A at 1100...

    Text Solution

    |

  14. A step-down transformer is used on a 1000 V line to deliver 20A at 120...

    Text Solution

    |

  15. A step-down transfomer reduces the voltage of a transmission line from...

    Text Solution

    |

  16. The number of turns of the primary and the secondary coils of a transf...

    Text Solution

    |

  17. A transformer of efficiency 90% draws an imput power of 4kw. An electr...

    Text Solution

    |

  18. A 220 V input is supplied to a transformer. The output circuit draws a...

    Text Solution

    |

  19. Which of the following is not an application of eddy currents?

    Text Solution

    |

  20. Eddy currents are produced when

    Text Solution

    |