Home
Class 12
PHYSICS
In meter brigde of Wheatstone bridge for...

In meter brigde of Wheatstone bridge for measurment of resistance, the known and the unknown resistance are interchanged. The error so removed is

A

end correction

B

index error

C

due to temperature effect

D

randon error

Text Solution

Verified by Experts

The correct Answer is:
A
Promotional Banner

Topper's Solved these Questions

  • CURRENT ELECTRICITY

    NARAYNA|Exercise Level 1 C.W|64 Videos
  • CURRENT ELECTRICITY

    NARAYNA|Exercise Level 1 H.W|63 Videos
  • CURRENT ELECTRICITY

    NARAYNA|Exercise Level 6|43 Videos
  • COMMUNICATION SYSTEM

    NARAYNA|Exercise Level-II(H.W)|25 Videos
  • DUAL NATURE OF RADIATION AND MATTER

    NARAYNA|Exercise ASSERTION AND REASON|15 Videos

Similar Questions

Explore conceptually related problems

Which error of meter bridge is removed when the known and unknown resistances are interchanged?

Wheatstone bridge is not suitable for the measurement of resistance of the order of

Wheatstone Bridge is not suitable for measurement of

In a Wheatstone bridge resistance connected the bridge is balanced , when the resistance are in the ratio

What are the advantages of a Wheatstone bridge method of measuring resistance over other methods ?

A meter bridge cannot be used to measure …… resistances

Wheatstone's bridge cannot be used for measurnment of very ………….. Resistance.

NARAYNA-CURRENT ELECTRICITY-C.U.Q
  1. Metal wire is connected in the left gap, semi conductor is connected i...

    Text Solution

    |

  2. A metre bridge is balanced with known resistance in the right gap and ...

    Text Solution

    |

  3. In meter brigde of Wheatstone bridge for measurment of resistance, the...

    Text Solution

    |

  4. In a metre-bridge experiment, when the resistances in the gaps in the ...

    Text Solution

    |

  5. Assertion: meterbridge wire is made up of manganin Reason: The tempe...

    Text Solution

    |

  6. Potentiometer is superior to voltmeter because

    Text Solution

    |

  7. In comparing emf's of 2 cells with the helf of potentiometer, at the b...

    Text Solution

    |

  8. A potentiometer wire is connectd across the ideal battery now, the rad...

    Text Solution

    |

  9. In a potentiometer of ten wires each of 1m, the balance point is obtai...

    Text Solution

    |

  10. If the emf of the cell in the primary circuit is doubled, with out cha...

    Text Solution

    |

  11. The potential gradients on the potentiometer wire are V(1) and V(2) wi...

    Text Solution

    |

  12. If the current in the primary circuit is decreased, then balancing len...

    Text Solution

    |

  13. Temperature coefficient of resistance alpha and resistivity rho of a p...

    Text Solution

    |

  14. A series high resistance is preferable than shunt resistance in the ga...

    Text Solution

    |

  15. Sensitivity of potentiometer can be increased by

    Text Solution

    |

  16. A cell of emf E and internal resistance r connected in the secondary g...

    Text Solution

    |

  17. Potentiometer is an ideal instrument because

    Text Solution

    |

  18. On increasing the resistance of the primary circuit of potentiometer, ...

    Text Solution

    |

  19. If the value of potential gradient on potentiometer wire is decreased,...

    Text Solution

    |

  20. A cell of negligible internal resistance is connected to a potentiomet...

    Text Solution

    |