Home
Class 12
PHYSICS
The themo emf of a copper-constantan the...

The themo emf of a copper-constantan thermocouple is `40muV.^(@)C^(-1)` at room temperature. A galvanometer whose resistance is `80 Omega` and current sensitivity `1 muA` is used. Find the smallest temperature difference that the galvanometer can detect.

Text Solution

Verified by Experts

The correct Answer is:
`2^(@)`C
Promotional Banner

Topper's Solved these Questions

  • THERMOELECTRICITY

    SL ARORA|Exercise Problem|2 Videos
  • SOLIDS AND SEMICONDUCTOR DEVICES

    SL ARORA|Exercise PROBLEM_TYPE|9 Videos
  • TRANSIENT CURRENT

    SL ARORA|Exercise Type D|13 Videos

Similar Questions

Explore conceptually related problems

The thermo emf of a thermocouple is 40 mu V K^(-1) at room temperature. A galvanometer of resistance 100 Omega capable of detecting current as law as 10 muA is connected with one such thermocouple. Calculate the smallest temperature difference that can be detected by such a thermocouple.

The thermo e.m.f. of a thermo- couple is 25 muV//^@C at room temperature. A galvanometer of 40 ohm resistance, capable of detecting current as low as 10^(-5) A, is connected with the thermo couple. The smallest temperature difference that can be detected by this system is

Near room temperature , the thermo emf of a thermo couple is 40 muV per degree. A galvanometer of 25 Omega and capable of detecting current of the order of 4 mu A is used. Calcualate the smallest temperature difference that can be detected with this galvanometer.

A thermocouple of negligible resistance produces an emf fo 40 mu V//^(@)C in the linear range of temperature. A galvanometer of resistance 10 Omega whose sensitivity is 1 mu A//div is employed with the thermocouple. The smallest value of temperature difference that can be detected by the system will

E.M.F. of a thermocouple is 25 mV//.^(@)C A galvanometer whose resistance is 40W, reads, 10^(-5)A curren then minimum temperature which is determined by if will be

A galvanometer of resistance 22.8Omega measures 1 A. How much shut should be used , so that it can be used to measure 20 A ?

Near room t emperature, the thermo emf of a copper constantan couple is 40 muV per degree. What is the smallest temperature difference that can be detected with a single such couple and a galvanometer of 100 ohm resistance capable of detecting current as low 10^(-6) ampere?

A galvanometer has coil resistance of 99 Omega with its full deflection current 0.01A. Find the value ofshnnt resistance required to convert it into an ammeter of range 0.1 A .