Home
Class 12
PHYSICS
Assertion: The tangent galvanometer can ...

Assertion: The tangent galvanometer can be made more sensitive by increasing the number of turns of its coil.
Reason: Current through galvanometer is proportional to the number of turns of coil.

A

If both assertion and reason are true and reason is the correct explanation of assertion.

B

If both assertion and reason are true but reason is not the correct explanation of assertion.

C

If assertion is true but reason is false.

D

If assertion and reason both are false.

Text Solution

Verified by Experts

The correct Answer is:
B

In tangent galvanometer the current through the coil is given `I=(2r)/(nmu_(0)).B_(H) tan thetaimplies tan theta prop n//r`
i.e., by reducing its radius or by increasing number of turns of coil we can increase the sensitivity of tangent galvanometer.
Promotional Banner

Topper's Solved these Questions

  • MAGNETISM AND MATTER

    A2Z|Exercise AIPMTNEET Questions|26 Videos
  • MAGNETISM AND MATTER

    A2Z|Exercise AIIMS Questions|23 Videos
  • MAGNETISM AND MATTER

    A2Z|Exercise Problems Based On Mixed Concepts|37 Videos
  • GEOMETRICAL OPTICS

    A2Z|Exercise Section D - Chapter End Test|30 Videos
  • MOCK TEST

    A2Z|Exercise Mock Test 3|44 Videos

Similar Questions

Explore conceptually related problems

Decreases in number of turns of coil in tangent galvanometer is

Show that the current flowing through a moving coil galvanometer is directly proportional to the angle of deflection of coil.

A moving coil galvanometer has number of turns 'N' in its coil. Then its sensitivity is in proportional to :-

A tangent galvanometer is connected directly to an ideal battery. If the number of turns in the coil is doubled, the deflection will

A current is sent through two tangent galvenometers in series. The deflectionis seen to be the same in both the galvanometer. Compare the radii of the coils of the galvanometer, if the number of turns in the coil of the first galvanometer is 110 and in the second 25.

The sensitiveness of a moving coil galvanometer can be increased by decreasing

A2Z-MAGNETISM AND MATTER-Section B - Assertion Reasoning
  1. Assertion: Basic difference between an electric line and magnetic line...

    Text Solution

    |

  2. Assertion: Magnetic moment of an atoms is due to both, the orbital mot...

    Text Solution

    |

  3. Assertion: When radius of circular loop carrying current is doubled, i...

    Text Solution

    |

  4. Assertion: A compass needle when placed on the magnetic north pole of ...

    Text Solution

    |

  5. Assertion: The tangent galvanometer can be made more sensitive by incr...

    Text Solution

    |

  6. Assertion: The ferromagnetic substance do not obey Curie's law. Reas...

    Text Solution

    |

  7. Assertion: Soft iron is used as transformer core. Reason: Soft iron ...

    Text Solution

    |

  8. Assertion: Magnetism is relativistic. Reason: When we move along wit...

    Text Solution

    |

  9. Assertion: The earth's magnetic field does not affect the working of a...

    Text Solution

    |

  10. Assertion: A paramagnetic sample display greater magnetisation (for th...

    Text Solution

    |

  11. Assertion: When a magnet is brought near iron nails, only translatory ...

    Text Solution

    |

  12. Assertion: When a magnetic dipole is placed in a non-uniform magnetic ...

    Text Solution

    |

  13. Assertion: Reduction factor (K) of a tangent galvanometer helps in red...

    Text Solution

    |

  14. Assertion: The permeability of a ferromagnetic material is independent...

    Text Solution

    |

  15. Assertion: Magnetic moment of helium atom is zero. Reason: All the e...

    Text Solution

    |

  16. Assertion: For making permanent magnets, steel preferred over soft iro...

    Text Solution

    |